| Specifications for Centurion |
| Dimensions and Weight | |
| Enclosure Width | |
| Enclosure Height | |
| Enclosure Depth | |
| Enclosure and Panel Weight | |
| Environmental Specifications | |
| Temperature | - 42°F to 100°F (5.6°C to 37.8°C),
operating
|
| Humidity | - 20% to 80% noncondensing,
operating and storing
|
| Altitude Range | - -1000 ft to 8000 ft operating,
up to 25,000 ft storing
- (-305 m to 2438 m operating,
up to 7620 m storing)
|
| Power Specifications | |
| Primary Power Transformer Type | - North America: Class 2, isolated, low-voltage
- Europe: User-supplied;must be Class 3 and connected to safety low-voltage source
|
| Primary Power Transformer Input | - North America: 110-120 VAC, 60 Hz, at 0.10 A
- Europe: 220-240 VAC, 50 Hz, at 0.06 A
|
| Primary Power Transformer Output | - North America and Europe: 12 VAC, 12 VA, at 1.0 A minimum
|
| Centurion Panel Input Voltage | - AC: 12 VAC, 50-60 Hz, at 0.75 A maximum
- DC: 12 VDC
|
| Relay Rating | |
| Card Reader Power | - 5.3 or 9.6 VDC at 100 mA max
|
| Memory Backup | - Lithium coin cell, 3.0 VDC,
type CR1620
|
| Fuse Type and Rating | - 1.0 A, 125 V, user-replaceable, slowblow, Nano SMF type, Littelfuse P/N
0454001
|
| Fuse location | - FU1, above power-entry plug-in
connector TB2
|
| Wiring Requirements | |
| Power to Centurion | - Panel 16-18 AWG.Maximum length: 32.8
feet (10 meters). One four-foot cable
connected to the transformer is
provided by IDenticard.
|
RS-232 (for connection to programming device) | - 3-conductor, 22 AWG, stranded,with
overall shield.West Penn No. 301.
One ten-foot cable with connectors
|
RS-485 (for connection to programming device) | - Twisted pair, 18-22 AWG with overall
shield.West Penn No. 291 (22 AWG),
West Penn No. 292 (20 AWG),West
Penn No. 293 (18 AWG).
- Maximum cable length: 4000 feet
(1219 meters) of wire, total copper,
including drops.
|
| Communications Specifications | |
| To Programming Device | - RS-232, DTE, via 9-pin male
Centurion serial port to PC serial port
or to NetLink Converter Channel 2
- RS-485, via 2-pin Centurion terminal
block connector to NetLink Converter
Channel 1 or RS-485 Centurion
Converter
|
| To Dial-Up Modem | - Modem can be connected via
Centurion serial port. See modem
manufacturer’s instructions for
specific connection requirements.
|
| Access Control Specifications | |
| Relay Pulse Time | |
| Door-Position Time | |
| Card Programming | - 2500 cards maximum per panel
|
| Indicators | |
| Visible | |
| Computer Requirements | |
| Hardware Requirements | - Available serial port for connection
to dial-up modem or local
|
| Operating System Requirements | - Windows® 2000 or Windows® XP
|